Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Acquisition Matrix' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Acquisition Matrix' found in 2 terms [] and 10 definitions [], (+ 5 Boolean[] results
previous     16 - 17 (of 17)     
Result Pages : [1]  [2 3]  [4]
Searchterm 'Acquisition Matrix' was also found in the following service: 
spacer
Forum  (1)  
 
Segmented HASTE
 
A variation of the (Half Fourier Acquisition Single Shot Turbo Spin Echo) HASTE sequence, whereat half of the image information is acquired after the first excitation pulse, and the half after the second excitation pulse. The acquired data are then interleaved into the raw data matrix. A long time to repetition (TR) is selected to allow the spin system to recover between excitation pulses and the dead time is used for additional slices. The length of the echo train is cut in half. Also more than 2 segments are possible.
spacer
MRI Resources 
Homepages - Coils - MR Guided Interventions - Case Studies - Colonography - Used and Refurbished MRI Equipment
 
Raw DataForum -
related threads
 
The Mx and My data (digital MR signal) sampled and stored during data acquisition as a function of time and phase from an MRI sequence are called raw data. The horizontal axis is the frequency code, the vertical axis the phase code (of the protons).
Every point in the raw data matrix contains part of the information for the complete image. A point in the raw data matrix does not correspond to a point in the image matrix. The outer rows of the raw data matrix provide information regarding the borders and contours of the image, detailed structures, and also determine the resolution. This is also called k-space data.
spacer

• View the DATABASE results for 'Raw Data' (23).Open this link in a new window

 
Further Reading:
  Basics:
MR Image Reconstruction from Raw Data
   by dukemil.egr.duke.edu    
MRI Resources 
Nerve Stimulator - NMR - Equipment - Liver Imaging - Directories - Societies
 
previous      16 - 17 (of 17)     
Result Pages : [1]  [2 3]  [4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 